Home / Products / Fire Resistance Tester /

EN136 Full Face Mask Thermal Radiation Resistance Test Machine For Personal Protect Equipment

Contact Now
Chongqing gold mechnical and electrical equipment Co., Ltd
Visit Website
City:chongqing
Province/State:chongqing
Country/Region:china
Contact Person:MrsIvy Zhang
Contact Now

EN136 Full Face Mask Thermal Radiation Resistance Test Machine For Personal Protect Equipment

Ask Latest Price
Video Channel
Brand Name :Gold
Model Number :GD-EN136
Certification :ISO
Place of Origin :CHINA
MOQ :1
Price :Negotiable
Payment Terms :L/C, D/A, D/P, T/T, Western Union, MoneyGram
Supply Ability :1 Set per 60 days
Delivery Time :60days
Packaging Details :Standard Wooden Case
Name :Full Face Mask Thermal Radiation Resistance Test Machine
Standard :EN 136 EN 13274
size :1,400 (W) × 600 (D) × 1,400 (H) mm
Power :AC 220V, 50 / 60Hz, 30A
weight :80kg
HRR :7.0~9.0 kW / m2
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

EN 136 Full Face Mask Thermal Radiation Resistance Test Machine

product introduce

The EN 136 full-face mask thermal radiation test machine evaluates heat and flame resistance for SCBA masks used in firefighting and industrial rescue. Compliant with EN 136, ISO 16900-11, and NFPA 1981 standards, it measures material integrity, seal performance, and visibility under high heat flux (≥10 kW/m²). Essential for certifying respiratory safety in extreme environments.

EN136 Full Face Mask Thermal Radiation Resistance Test Machine For Personal Protect Equipment

Standard

1. EN 136:1998


Name: Respiratory protective devices Self-contained open-circuit compressed air breathing apparatus


Content: Specifies the protective performance requirements of full-face masks in high temperature, flame or thermal radiation environments, including sealing, field of view and material heat resistance tests.

2. EN 13274-3:2001


Name: Respiratory protective devices Methods of test Part 3: Determination of breathing resistance


Related test: Combined with thermal radiation test, evaluate the change of breathing resistance of the mask under high heat conditions.

3. EN 13274-4:2001


Name: Part 4: Flame tests


Content: Directly involves the flame retardancy test of the mask material under flame exposure to ensure that it does not melt or continue to burn in the fire.

Other relevant standards


1. ISO 16900-11:2019


Name: Respiratory protective devices Methods of test and test equipment Part 11: Determination of flame resistance


Application: Flame retardant test method of the International Organization for Standardization (ISO), complementary to EN 136, suitable for global certification.

2. NFPA 1981 (2020)


Name: Standard on Open-Circuit Self-Contained Breathing Apparatus (SCBA) for Emergency Services


Test requirements: National Fire Protection Association standard, specifies the test method for the thermal radiation and flame protection performance of SCBA masks.

Features

1, Cabinet paint treatment, beautiful; all toolings are made of stainless steel production, appearance, corrosion resistance;

2, PLC and touch screen control systems; test interface is easy to operate;

3, The system automatically timing, the thermal data is automatically recorded and stored;

4, Various test reports independent storage and freedom retrieval;

5, Computer control system, automatic timing, the heat data is automatically recorded and stored;

6, Metal head mould, heat-resistant, corrosion-resistant;

7, The distance between radiation source and the metal mould is 175mm, the HRR at this location is 7.0~9.0 kW / m2;

8, US imports of heat meter to accurately detect the radiant heat;

9, Temperature controller controls the heat release rate of the heat radiating device (resolution: 0.1kW / m2)

10, Radiation clapboard free for extraction and placement.

11, Head-mould moving is base on the slide design,

12, Breathing apparatus: artificial respiration can be carried out during the testing process; artificial breathing device work 10-30 times per minute, each circle 1.0~2.5L,

13, PLC automatic control device,

Specification:

Size 1,400 (W) × 600 (D) × 1,400 (H) mm
Power AC 220V, 50 / 60Hz, 30A
Weight 80kg

Inquiry Cart 0