Chongqing gold mechnical and electrical equipment Co., Ltd

Chongqing gold mechnical and electrical equipment Co., Ltd

Manufacturer from China
Verified Supplier
1 Years
Home / Products / Cable Fire Resistance Tester /

High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2

Contact Now
Chongqing gold mechnical and electrical equipment Co., Ltd
Visit Website
City:chongqing
Province/State:chongqing
Country/Region:china
Contact Person:MrsIvy Zhang
Contact Now

High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2

Ask Latest Price
Video Channel
Brand Name :GOLD
Certification :ISO
Place of Origin :China
MOQ :1 set
Price :USD 2000-6000
Payment Terms :L/C,T/T
Supply Ability :10 sets per month
Delivery Time :20 working days
Packaging Details :Plywood case
Product :Limiting oxygen index tester
Standard :ISO 4589-2
Application :Cable fire resistance test
Flow meter :160~1600L/H adjustable
Pressure gauge accuracy :2.5 level
Resolution of oxygen concentration indicator :0.1%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Fire Resistance of Plastics: Limiting Oxygen Index (LOI) tester ISO 4589-2

Oxygen index refers to the minimum oxygen concentration required for a material to burn with a flame in an oxygen-nitrogen mixed gas flow under specific test conditions. It is expressed as a volume fraction and is an important indicator for evaluating the combustion performance of a material. The higher the limiting oxygen index, the more difficult the material is to burn. It is generally believed that materials above 27% are difficult to burn, and materials below 20% are flammable.

Principle and method of the Limiting Oxygen Index Tester:

1. Principle:

Under specified conditions, ignite the material in an oxygen-nitrogen mixed gas flow and measure the minimum oxygen concentration required to maintain its combustion.

2. Method:

Oxygen index meter: Use oxygen and nitrogen mixed in proportion, accurately control the gas flow rate, and measure the minimum oxygen concentration required to maintain the combustion of the sample.

3. Test standard:

Different materials and application scenarios have different test standards, such as ISO 4589-2 (room temperature oxygen index) and ISO 4589-3 (high temperature oxygen index).

Technical parameters:

  • Inner diameter of combustion tube 90mm.
  • Height of combustion tube 450mm.
  • Diameter of the tube hole at the tail end of the long rod igniter: φ2±1mm.
  • Flow meter: 160~1600L/H adjustable.
  • Pressure gauge accuracy is 2.5 levels.
  • Pressure gauge resolution: 0.01MPa.
  • Resolution of oxygen concentration indicator: 0.1%.
  • Oxygen sensor: High-precision oxygen sensor imported from Germany.
  • Gas source: Oxygen specified in GB3863, nitrogen specified in GB3864.
  • Test environment: temperature 10-35℃, humidity 45-75%.
  • Input pressure: 0.2- 0.3MPa.
  • Working pressure: 0.05- 0.15MPa.
  • Sample type: self-supporting material and non-self-supporting material.

High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2

High Accuracy LOI Tester Limiting Oxygen Index Of Pvc ISO 4589-2

Specification:

Control box dimensions

460mm(L)×420mm(W)×760mm(H);

Combustion tube base dimensions

250mm×250mm×550mm;

Power supply

AC220V, 50/60Hz, DC 1A;

Gas source

oxygen, nitrogen (provided by the customer).

Inquiry Cart 0